Battery Combiner 200
SPECIFICATIONS
(For Alternators up to 200-Amps)
• Suitable for alternators up to 200-Amps with
175-Amp continuous rating, 400-Amp closing
current, and charging levels up to 18-Volts
• Combiner 200 switches to charge mode when the
lead-acid battery being charged reaches 13.3-Volts
• Supplied 6-Gauge crimp terminals and 5/16-18
studs and hex nuts for connecting customer supplied
6-AWG cable leads to battery positive (+) posts.
Connect customer supplied ground cable to 4-40
threaded post labeled NEGATIVE (-) on the
Combiner 200
Features & Specifications
• Protects alternator against overload from low battery levels
• Waterproof and Ignition rated for explosive atmosphere
• Electronic thermal monitoring with shutdown & restart
• Can be used on alternators with internal regulators
• Green LED Indicates when combined for charging, and red
LED Indicates Overload or Low Voltage Detected Condition
• Draws no current when batteries are not being charged
and less than 150-Milliamps when charging is in progress,
so no heat sinking or cooling required
• No diodes to burn out if accidentally shorted
• Withstands ambient temperature to over 175°F (80°C)
for exposed or engine compartment installations
• No special wiring for alternators with external sense
• Optional external remote for Off/Automatic/On.
Remote “ON” can be used for assisted engine starting
• One (1) year factory-direct limited warranty